Scientific novelty: Determined that with a fixed value of the power factor and the value of conductivity bc, it is very difficult to achieve ideal current resonance, and when bc = −⌂bl+bl+⌂blс the
burning mode of the electric arc will be continuous; however, if the capacitive conductivity becomes
more inductive, overcompensation is possible. In the case of transverse compensation, the total power
of the furnace unit should be approximately 10% higher.
Practical significance: The results obtained can be used for a reasoned selection of reactive
power compensation installations for existing ore reduction electric furnaces. With full compensation of the reactive power (transverse and longitudinal), the arc burning mode of the ore reduction furnace
becomes intermittent. Наукова новизна. Встановлено, що при фіксованому значенні коефіцієнта потужності та значенні провідності bc дуже важко досягти ідеального резонансу струму, а при bc = −⌂bl+bl+⌂blс
режим горіння електричної дуги буде безперервний; однак, якщо ємнісна провідність стає
більш індуктивною, можлива надмірна компенсація. При поперечній компенсації загальна потужність топкового агрегату повинна бути приблизно на 10% вище.
Практичне значення. Отримані результати можуть бути використані для обґрунтованого вибору установок компенсації реактивної потужності існуючих рудовідновних електропечей.
При повній компенсації реактивної потужності (поперечної і поздовжньої) режим горіння дуги
рудовідновної печі стає переривчастим.